1901 Central Avenue Permit History Home Tour Blue Prints Julia Morgan -- Project No. 304 |
||||||
This is not a substitute for an official history. Order your own from the City of Alameda Building Dept. | ||||||
Permit | Issued | Finaled | Work | |||
5/26/1910 | 2-S-8-R-D $6,670.00 Owner -- Fred Staude, Builder - Joseph Neil (Neal) | |||||
2598 | 10/20/1914 | Garage $150.00 | ||||
4332 | 4/22/1919 | Garage $100.00 | ||||
1752 | 10/22/1959 | Roofing $120.00 Owner -- Fred Staude | ||||
This was Fred Staude. Jr. not his father who had the house built in 1910. | ||||||
726 | 5/6/1964 | Remodeling $2,500.00 Plan #101A - Stanley Boersma and H. B. Ulrey | ||||
Stanley and Geurtje Boersma bought the house. They sold off the tennis court lot for $18,500. Ulrey mention is an error. | ||||||
E64-6206 | 6/9/1964 | Electrical Permit FINALED | ||||
9 CIRCUITS, 24 OUTLETS, 4 OUTLETS OVER 1000, 5 SWITCHES, | ||||||
7 FIXTURES, 9 PLUGS, 4 MOTORS, RANGE, DRYER, SERVICE CHANGE | ||||||
8/17/1965 | Property Division Map No. 150 filed. Remaining property is 54' wide and 120' deep. | |||||
10/xx/1965 | Permit for 1907 Central Apartment Building on 1901's tennis court lot - owner, Merrick Browne | |||||
1119 | 11/5/1970 | Alterations $1,000.00 Owner -- Stanley Boersma, H. B. Ulrey | ||||
Stanley and Geurtje Boersma sold the house to Harold B.Ulrey for $56,000. | ||||||
E70-2267 | 11/16/1970 | Electrical Permit FINALED 2 OUTLETS, 1 SWITCH, 1 FIXTURE | ||||
79-0928att | 8/7/1979 | Termite Repair $1,500.00 for Ulrey | ||||
6/30/1983 | Frank and Florence Rapp bought the house for $110,000 | |||||
S93-1147 | 11/4/1993 | Sidewalk FINAL MARY, TRIM BUSHES | ||||
MR09-0591 | 12/14/2009 | 12/14/2009 | Miscellaneous Revenue Finaled RICH KRINKS (G.C. Wagner's Realtor) | |||
PERMIT HISTORY | ||||||
P09-0974 | 12/21/2009 | 12/29/2009 | Plumbing Permit Finaled PIPE SPY INC | |||
INSTALL EARTHQUAKE SHUT OFF VALVE AT GAS METER | ||||||
MANUFACTURE: PACIFIC SEISMIC 3/4" MODEL: 300 HORIZONTAL | ||||||
P09-0975 | 12/21/2009 | 12/23/2008 | Plumbing Permit Finaled PIPE SPY INC | |||
REPLACE SEWER LATERAL W/TWO WAY KELLY AND TEST | ||||||
CB09-0881 | 12/22/2009 | 12/28/2009 | Combination Building Permit Finaled PIPE SPY INC | |||
INSTALL SUMP PUMP @ BOTTOM OF EXTERIOR STAIRWAY (PLBG/ELE/CONCRETE) | ||||||
C09-0135 | 12/22/2009 | 1/30/2012 | PublicWorks/Concrete Permit/Over the Counter/NA | |||
Concrete Permit Finaled PIPE SPY INC | ||||||
CONCRETE:INSTALL SUMP PUMP @ BOTTOM OF EXTERIOR STAIRWAY | ||||||
(REMOVE SIDEWALK PER P.W.) | ||||||
SW11-0252 | 9/27/2011 | 1/30/2012 | PublicWorks/Sidewalk/Property/NA | |||
12/29/2009 | Gerald C. Wagner bought the house for $900,000 | |||||
P10-0054 | 2/3/2010 | 2/9/2010 | Plumbing Permit Finaled ALBERT NAHMAN PLUMBING & HEATING | |||
INSTALL EARTHQUAKE SHUT OFF VALVE AT GAS METER MANUFACTURE: LITTLE FIRE | ||||||
FIGHTER 1 1/4" MODEL: AGV-125-5.0 HORIZONTAL | ||||||
P10-0055 | 2/3/2010 | 3/8/2010 | Plumbing Permit Finaled ALBERT NAHMAN PLUMBING & HEATING 02/03/2010 03/08/2010 | |||
RE-PIPE TO COPPER FROM METER TO HOUSE AND INSTALL TANK-LESS WATER HEATER | ||||||
WITH A DEDICATED 1-1/4" GAS LINE (10' LONG) (199,000 BTU'S) 02/23/10 REPLACE | ||||||
EXISTING GAS LINE TO FURNACE, STOVE AND DRYER (162,000 BTU'S) | ||||||
E10-0023 | 2/8/2010 | 5/5/2010 | Electrical Permit Finaled ROBERTS ELECTRIC CO. INC. | |||
REMOVE EXISTING METER, SERVICE CONDUIT AND WIRING. INSTALL NEW METER AT | ||||||
APPROXIMATE LOCATION OF EXISTING SERVICE. INSTALL NEW SERVICE RISER CONDUIT, | ||||||
WEATHERHEAD AND CONDUCTORS. UPGRADE MAIN SERVICE GROUNDING AND BONDING. | ||||||
INSTALL SUBPANEL IN BASEMENT. INSTALL 200 AMP SUBFEED FROM NEW METER MAIN TO | ||||||
BASEMENT MAIN SUBPANEL. INSTALL 70 SUBFEED IN "BLUE ROOM". INSTALL SUBFEED IN ATTIC. | ||||||
M10-0025 | 2/11/2010 | 3/9/2010 | Mechanical Permit Finaled LAVINE CO | |||
REMOVE & REPLACE FURNACE AND DUCTING @ BASEMENT AREA | ||||||
B10-0130 | 2/16/2010 | 12/15/2010 | Building Permit Finaled WAGNER GERALD | |||
INSTALL ADDITIONAL (25) 5/8" EPOXY BOLTS BETWEEN EACH OF EXISTING BOLTS TO CREATE | ||||||
3' ON CENTERS WITH AT LEAST 6 INCHES WASHER 3X3X.229 (HOUSE ALREADY EXISTS WITH | ||||||
30 3/4" BOLTS INBEDDED 16") / REMOVE LATH & PLASTER IN BASEMENT AND REPLACE NEW | ||||||
SHEAR PLYWOOD & NEW 2X4 FIR WITH NEW 5/8" DRYWALL | ||||||
CB10-0151 | 3/2/2010 | 12/15/2010 | Combination Building Permit Finaled WAGNER, GERALD | |||
CONVERT 381 SQ FT OF BASEMENT TO HABITABLE SPACE. ADD ONE LIGHT AND ONE PLUG EACH | ||||||
TO TWO STOREROOMS IN BASEMENT. REWIRE AND UPGRADE KITCHEN AND TV ROOM LIGHTS. | ||||||
This conditioned basement room is used as a home theater -- 'El Morocco' | ||||||
B10-0365 | 4/15/2010 | 5/5/2010 | Building Permit Finaled WAGNER GERALD C | |||
REMOVE REAR CHIMNEY DOWN TOWARD ROOF LINE AND CAP | ||||||
CB11-0077 | 2/2/2011 | 12/5/2011 | Approved 530-Final Combination Permit (3717159) | |||
INSTALL 2 IN-LINE EXHAUST FANS IN ATTIC WITH 6" DUCTS EXITING THROUGH VENTS IN REAR | ||||||
OF HOUSE (MECH/ELEC) | ||||||
CB11-0096 | 2/8/2011 | 5/25/2011 | Building Permit Finaled WAGNER GERALD C | |||
CONVERT 363 SQ FT OF BASEMENT TO HABITABLE SPACE (FIR 2 WALLS, SHEETROCK 4 WALLS & | ||||||
CEILING, INSTALL 3 OVERHEAD LIGHTS, 6 SCONCES & 9 DOUBLE OUTLETS) (BLDG/ELEC) | ||||||
This conditioned basement room is used as a hobby room (the 'City of Paris' room). | ||||||
PDR11-0028 | 6/8/2011 | 6/8/2011 | Due on 06/08/2011, assigned to TBD; Marked as Complete on 06/08/2011 by LA | |||
DESIGN REVIEW EXEMPTION ~ CONVERSION OF ATTIC TO HABITABLE SPACE. 742 SQUARE FEET | ||||||
AT THE 5'6" HEAD ROOM LEVEL. 930 SQFT TO THE KNEE WALL (2'6'/2'10") | ||||||
CB11-0463 | 6/8/2011 | 11/6/2012 | INSTALL ELECTRIC IN NON HABITABLE THIRD FLOOR ATTIC SPACE (1026 SQ.FT.); PARTIALLY | |||
SHEETROCK 2 END WALLS & UTILITY SPACE TO PROTECT ELECTRIC WIRING; INSTALL 10 | ||||||
OVERHEAD LIGHTS & 13 RECEPTACLES; AND REWIRE 2 TERRACE LIGHTS ABOVE 2ND FLOOR | ||||||
EXTERIOR DECK (OK TO USE FOR HOBBY/STUDIO AREA PER GREG MCFANN) (BLDG/ELEC) | ||||||
The attic permit is mainly electrical and allows hobby/studio use. OK given for using Redwood instead of sheetrock. | ||||||
B12-0641 | 7/25/2012 | 10/3/2012 | TEAR OFF AND REROOF FRONT PORCH (150 SQ.FT.) (CLASS 'A' CEDAR SHINGLE ROOF | |||
SYSTEM, BITUTHENE MEMBRANE ON DECK WITH 72 LB CAP SHEET WITH CLASS 'B' | ||||||
CEDAR SHINGLES) | ||||||
B12-0775 | 8/28/2012 | 10/3/2012 | FRONT STEPS REPAIR - REPLACE RISERS & TREADS OF FRONT PORCH & REPLACE SMALL | |||
AREA OF STUCCO TO MATCH | ||||||
PDR12-0367 | 10/18/2012 | 10/18/2012 | DR EXEMPTION TO REPLACE 200 SF OF DAMAGED SHINGLES LIKE FOR LIKE. LISTED AS "S" ON | |||
THE HRL. APPLICATION ALSO INCLUDES ADDITION OF AN EXTERIOR DOWNWARD-CAST LIGHT. | ||||||
CB12-0765 | 10/18/2012 | 11/7/2012 | REPLACE 200 SQ.FT. OF EXTERIOR SHINGLES ON WEST, REAR OF HOUSE; ADD ONE EXTERIOR | |||
LIGHT & 3 EXTERIOR ELECTRICAL RECEPTACLES (ONE EACH ON WEST, NORTH & EAST WALLS) | ||||||
(BLDG/ELEC) | ||||||
PLN13-0332 | 10/21/2013 | 10/21/2013 | HOME OCCUPATION - OFFICE FOR SOFTWARE ADMINISTRATION FOR BUSINESS, | |||
Approved |